Kategori | Alat Test kelistrikan |
Di lihat | 1412 kali |
Harga | Rp (hubungi cs) |
NEW – Large 50, 000 count, ¼ VGA display with white backlight. Multiple sets of measurement information can simultaneously displayed at the same time.
NEW – Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, monitoring unattended while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time, storing up to 10, 000 readings. Using on-board TrendCapture, you can graphically view logged readings without a PC. ( Software and interface cable optional) .
NEW – Log multiple sessions or log data continuously for over 200 hours. This is useful for characterizing the performance of a design or for unattended monitoring.
NEW – i-info button on board help screens for measurement functions. Unsure about a function? Go to that function and Press the “ i” button.
NEW – LoZ Volts. Low impedance voltage function prevents false readings due to “ ghost voltage.” It is also the recommended mode when testing for absence or presence of live power.
New – Low Pass Filter for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
50 ohm range – useful for measuring and comparing differences in motor winding resistance, low ohm measurements, or other contact resistance. Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
NEW – Saved measurements allow you to name and recall measurements made in the field
Real Time Clock – for automatic time stamping of saved readings
NEW – Field upgradeable and expandable meter lets you stsay current as new capabilities are added
NEW – Multi-lingual interface
Min/ Max/ Average with Time Stamp to record signal fluctuations
Soft keys, scroll buttons and easy navigation control access to secondary functions. Create custom displays too.
0.025% Basic DC accuracy
100 kHz ac bandwidth
True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads.
Measure up to 10A ( 20 A for 30 seconds; 10A continuous)
100 mF capacitance range
Temperature function
Relative mode to remove test lead resistance from low ohms or capacitance measurements
Peak capture to record transients as fast as 250 ¼ s
Premium test leads and alligator clips included
Optical USB PC communication interface allows for easy PC download to document logged data with FVF software ( not included) .
Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
Limited lifetime warranty
CAT III 1000 V / CAT IV 600 V safety rated
Specifications
Voltage DC
Accuracy 0.025 %
Range and Resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy 0.4 % ( true-rms)
Range and Resolution 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy 0.06 %
Range and Resolution 500.00 µ A, 5000.0 µ A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy 0.61 % ( true-rms)
Range and Resolution 500.00 µ A, 5000.0 µ A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature ( excluding probe)
Accuracy 1.0 %
Range and Resolution -200.0 ° C to 1350.0 ° C ( -328.0 ° F to 2462.0 ° F)
Resistance
Accuracy 0.05 %
Range and Resolution 500.00 & , 5.0000 k& , 50.000 k& , 500.00 k& , 5.0000 M& , 50.00 M& , 500.0 M&
Resistance 10 50 & ( 2 wire connection)
Accuracy 0.15 % + 20
Range and resolution 50.000 &
Capacitance
Accuracy 1.0 %
Range and Resolution 1.000 nF, 10.00 nF 100.0 nF, 1.000 µ F, 10.00 µ F, 100.0 µ F, 1000 µ F, 10.00 mF, 100.00 mF &
Frequency
Accuracy 0.005% + 5
Range and Resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/ features
Multiple on-screen displays Yes
True-rms AC bandwidth 100 kHz
DBV/ dBm Yes
DC mV resolution 1 ¼ V
Megohm range Up to 500 M
Conductance 50.00nS
Continuity beeper Yes
Battery/ Fuse access Battery / Fuse
Peak 250 ¼ S
Elapse time clock Yes
Time of day clock Yes
Min-Max-Avg Yes
Frequency Yes
Duty Cycle 0.01 % to 99.99 %
Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated Optical Interface Yes
Auto/ Touch Hold Yes
Reading memory Yes
Log to PC Yes
Interval/ Event Logging Yes
Logging Memory Up to 10, 000 readings
Resistance Low Ohm 0.001 © to 50.000 © 10 mA source
LoZ Yes
Low Pass Filter Yes
Environmental Specifications
Operating Temperature
-20 ° C to + 55 ° C
Storage Temperature
-40 ° C to + 60 ° C
Relative Humidity
0% to 90% ( 0 ° C – 37 ° C)
0% to 65% ( 37 ° C – 45 ° C) ,
0 to 45 % ( 45 ° C – 55 ° C
Electromagnetic Compatability
EMC EN6 1326-1
Vibration
Random vibration per MIL-PRF-28800f Class 2
Shock
1 meter drop per IEC/ EN 61010-1 2nd edition
Safety Specifications
Overvoltage category
CAT III 1000 V / CAT IV 600 V safety rated
Agency Approvals
CSA, UL, TÜ V, CE
Mechanical & General Specifications
Maximum voltage between any terminal and earth ground
1000V
Size
( HxWxL 22.2 cm x 10.2 cm x 6 cm ( 8.75 in x 4.03 in x 2.38 in)
Weight
870.9 g ( 28 oz)
Battery Life
100 minimum, 200 hours in logging mode
Battery type
6 AA alkaline batteries, NEDA 15A IEC LR6